Model NO.: RTA, JTA Series
Cooling Way: Water Cooled, Air Cooled, CHP, Cchp
Power Range: 160kw-1450kw
Gas Methane: Gas Low Heat Value Over 36mj/Nm3
Certticates: ISO, CE, BV, GOST, SGS, etc
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: China
HS Code: 8502120000
Model NO.: RTA, JTA Series
Cooling Way: Water Cooled, Air Cooled, CHP, Cchp
Power Range: 160kw-1450kw
Gas Methane: Gas Low Heat Value Over 36mj/Nm3
Certticates: ISO, CE, BV, GOST, SGS, etc
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: China
HS Code: 8502120000
50Hz 1500RPM Googol Natural Gas Engine for Generator 160kW-1450kW
Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Engine Model |
 |
RTA780G1 |
RTA780G3 |
RTA890G1 |
RTA1120G1 |
RTA1340G1 |
JTA2160G1 |
JTA2160G3 |
JTA3240G3 |
JTA4320G1 |
JTA4320G3 |
Rating Speed |
rpm |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
Generator Output (COP) |
kW |
160Â |
200Â |
250Â |
320Â |
400Â |
600Â |
720Â |
1024Â |
1280Â |
1452Â |
Power Factor |
 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
Gas Engine Parameter |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Engine Output  (COP) |
kW |
180Â |
222Â |
278Â |
355Â |
438Â |
629Â |
751Â |
1069Â |
1331Â |
1503Â |
Air Ratio |
λ |
1.65Â |
1.7Â |
1.7Â |
1.7Â |
1.7Â |
1.67Â |
1.7Â |
1.7Â |
1.65Â |
1.7Â |
Configuration |
 |
6 In line |
6 In line |
8Â Vee |
10Â Vee |
12Â Vee |
8Â Vee |
8Â Vee |
12Â Vee |
16Â Vee |
16Â Vee |
Displacement |
l |
12.8 |
12.8 |
14.6 |
18.3 |
21.9 |
35.4 |
35.4 |
53.1 |
70.8 |
70.8 |
Bore |
mm |
128 |
128 |
128 |
128 |
128 |
170 |
170 |
170 |
170 |
170 |
Stroke |
mm |
166 |
166 |
142 |
142 |
142 |
195 |
195 |
195 |
195 |
195 |
Compression Ratio |
 |
11:1 |
11:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
Piston Speed |
m/s |
8.3 |
8.3 |
7.1 |
7.1 |
7.1 |
9.75 |
9.75 |
9.75 |
9.75 |
9.75 |
Number of Flywheel Teeth |
 |
160Â |
160Â |
160Â |
160Â |
160Â |
218Â |
218Â |
218Â |
218Â |
218Â |
Flywheel House Size |
 |
SAE1-14 |
SAE1-14 |
SAE1-14 |
SAE1-14 |
SAE1-14 |
SAE00-18 |
SAE00-18 |
SAE00-21 |
SAE00-21 |
SAE00-21 |
System Parameter |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Oil Capacity |
l |
40 |
40 |
70 |
80 |
90 |
160 |
160 |
180 |
240 |
240 |
Max. Allowed Oil Temperature |
°C |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
Oil Pressure Warning |
kPa |
200Â |
200Â |
200Â |
200Â |
200Â |
300Â |
300Â |
300Â |
300Â |
300Â |
Oil Pressure Shutdown |
kPa |
160Â |
160Â |
160Â |
160Â |
160Â |
200Â |
200Â |
200Â |
200Â |
200Â |
Coolant Capacity for Engine |
l |
18 |
18 |
36 |
42 |
44 |
70 |
70 |
100 |
140 |
140 |
Max. Coolant Warning Temperature  |
°C |
90 |
90 |
90 |
90 |
90 |
95 |
95 |
95 |
95 |
95 |
Max. Coolant Shutdown Temperature  |
°C |
95 |
95 |
95 |
95 |
95 |
100 |
100 |
100 |
100 |
100 |
Max. Intercooler Outlet Temperature  |
°C |
50 |
50 |
50 |
50 |
50 |
40.5 |
40.5 |
40.5 |
40.5 |
40.5 |
Flow of Coolant pump (JW) |
m³/h |
20 |
20 |
26 |
26 |
26 |
48 |
48 |
48 |
80 |
80 |
Flow of Coolant pump (LT) |
m³/h |
14 |
14 |
14 |
14 |
14 |
45 |
45 |
45 |
75 |
75 |
Max. Exhaust Temperature |
°C |
500 |
500 |
500 |
500 |
500 |
480 |
480 |
480 |
480 |
480 |
Exhaust Flow |
kg/h |
776 |
776 |
943 |
1232 |
1520 |
3264 |
3896 |
5523 |
6891 |
7887 |
Exhaust Flange Diameter |
mm |
1*125 |
1*125 |
2*125 |
2*125 |
2*125 |
1*250 |
1*250 |
1*250 |
1*250 |
1*250 |
Charging Alternator Capacity |
A |
35 |
35 |
35 |
35 |
35 |
55 |
55 |
55 |
55 |
55 |
Starting Voltage |
V |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
Thermal Balance |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
JW Coolant Heat |
± 8% kW |
99 |
122 |
142 |
184 |
220 |
317 |
372 |
532 |
678 |
769 |
CAC Intercooler Heat |
± 8% kW |
 |
 |
 |
 |
 |
50 |
60 |
85 |
107 |
121 |
Exhaust Heat up to 120°C |
± 8% kW |
115 |
142 |
161 |
208 |
265 |
364 |
431 |
571 |
709 |
802 |
Energy Input |
 kW |
462Â |
571Â |
679Â |
860Â |
1067Â |
1531Â |
1809Â |
2504Â |
3160Â |
3559Â |
ELectrical Efficiency |
% |
34.6 |
35 |
36.8Â |
37.2Â |
37.5Â |
39.2Â |
39.8Â |
40.9Â |
40.5Â |
40.8Â |
Mechanical Efficiency |
% |
37.2Â |
37.4Â |
39.3Â |
39.7Â |
39.8Â |
41.1Â |
41.5Â |
42.5Â |
42.0Â |
42.2Â |
Thermal Efficiency |
% |
46.3Â |
46.2Â |
44.6Â |
45.6Â |
45.5Â |
44.5Â |
44.4Â |
44.1Â |
43.9Â |
44.1Â |
Total Efficiency |
% |
80.9Â |
81.2Â |
81.4Â |
82.8Â |
83.0Â |
83.7Â |
84.2Â |
85.0Â |
84.4Â |
84.9Â |
Gas Consumption |
MJ/kWh |
10.40Â |
10.29Â |
9.78Â |
9.68Â |
9.60Â |
9.18Â |
9.05Â |
8.80Â |
8.89Â |
8.82Â |
Generator Parameter-MECC ALTE |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Generator Model |
 |
ECO38-3SN/4 |
ECO38-2LN/4 |
ECO38-3LN/4 |
ECO40-2S/4 |
ECO40-1L/4 |
ECO43-2SN/4 |
ECO43-1LN/4 |
ECO43-VL/4 |
ECO46-2S/4 |
ECO46-1L/4 |
Generator Prime Output |
kW |
180 |
240 |
280 |
360 |
440 |
744 |
880 |
1120 |
1440 |
1680 |
Generator Efficiency @ 0.8PF |
 |
93.0% |
93.5% |
93.6% |
93.7% |
94.2% |
95.4% |
95.9% |
96.2% |
96.4% |
96.6% |
Genset Dimension |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Length |
mm |
3100 |
3100 |
3300 |
3500 |
3600 |
4600 |
4600 |
4500 |
5000 |
5000 |
Width |
mm |
1300 |
1300 |
1500 |
1500 |
1500 |
2190 |
2190 |
1600 |
1600 |
1600 |
Height |
mm |
1700 |
1700 |
2000 |
2000 |
2000 |
2300 |
2300 |
2200 |
2300 |
2300 |
Genset Weight |
kg |
2500 |
2500 |
3500 |
3900 |
4300 |
7350 |
7650 |
10500 |
13500 |
13500 |

50Hz 1500RPM Googol Natural Gas Engine for Generator 160kW-1450kW
Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Engine Model |
 |
RTA780G1 |
RTA780G3 |
RTA890G1 |
RTA1120G1 |
RTA1340G1 |
JTA2160G1 |
JTA2160G3 |
JTA3240G3 |
JTA4320G1 |
JTA4320G3 |
Rating Speed |
rpm |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
Generator Output (COP) |
kW |
160Â |
200Â |
250Â |
320Â |
400Â |
600Â |
720Â |
1024Â |
1280Â |
1452Â |
Power Factor |
 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
Gas Engine Parameter |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Engine Output  (COP) |
kW |
180Â |
222Â |
278Â |
355Â |
438Â |
629Â |
751Â |
1069Â |
1331Â |
1503Â |
Air Ratio |
λ |
1.65Â |
1.7Â |
1.7Â |
1.7Â |
1.7Â |
1.67Â |
1.7Â |
1.7Â |
1.65Â |
1.7Â |
Configuration |
 |
6 In line |
6 In line |
8Â Vee |
10Â Vee |
12Â Vee |
8Â Vee |
8Â Vee |
12Â Vee |
16Â Vee |
16Â Vee |
Displacement |
l |
12.8 |
12.8 |
14.6 |
18.3 |
21.9 |
35.4 |
35.4 |
53.1 |
70.8 |
70.8 |
Bore |
mm |
128 |
128 |
128 |
128 |
128 |
170 |
170 |
170 |
170 |
170 |
Stroke |
mm |
166 |
166 |
142 |
142 |
142 |
195 |
195 |
195 |
195 |
195 |
Compression Ratio |
 |
11:1 |
11:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
12:1 |
Piston Speed |
m/s |
8.3 |
8.3 |
7.1 |
7.1 |
7.1 |
9.75 |
9.75 |
9.75 |
9.75 |
9.75 |
Number of Flywheel Teeth |
 |
160Â |
160Â |
160Â |
160Â |
160Â |
218Â |
218Â |
218Â |
218Â |
218Â |
Flywheel House Size |
 |
SAE1-14 |
SAE1-14 |
SAE1-14 |
SAE1-14 |
SAE1-14 |
SAE00-18 |
SAE00-18 |
SAE00-21 |
SAE00-21 |
SAE00-21 |
System Parameter |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Oil Capacity |
l |
40 |
40 |
70 |
80 |
90 |
160 |
160 |
180 |
240 |
240 |
Max. Allowed Oil Temperature |
°C |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
Oil Pressure Warning |
kPa |
200Â |
200Â |
200Â |
200Â |
200Â |
300Â |
300Â |
300Â |
300Â |
300Â |
Oil Pressure Shutdown |
kPa |
160Â |
160Â |
160Â |
160Â |
160Â |
200Â |
200Â |
200Â |
200Â |
200Â |
Coolant Capacity for Engine |
l |
18 |
18 |
36 |
42 |
44 |
70 |
70 |
100 |
140 |
140 |
Max. Coolant Warning Temperature  |
°C |
90 |
90 |
90 |
90 |
90 |
95 |
95 |
95 |
95 |
95 |
Max. Coolant Shutdown Temperature  |
°C |
95 |
95 |
95 |
95 |
95 |
100 |
100 |
100 |
100 |
100 |
Max. Intercooler Outlet Temperature  |
°C |
50 |
50 |
50 |
50 |
50 |
40.5 |
40.5 |
40.5 |
40.5 |
40.5 |
Flow of Coolant pump (JW) |
m³/h |
20 |
20 |
26 |
26 |
26 |
48 |
48 |
48 |
80 |
80 |
Flow of Coolant pump (LT) |
m³/h |
14 |
14 |
14 |
14 |
14 |
45 |
45 |
45 |
75 |
75 |
Max. Exhaust Temperature |
°C |
500 |
500 |
500 |
500 |
500 |
480 |
480 |
480 |
480 |
480 |
Exhaust Flow |
kg/h |
776 |
776 |
943 |
1232 |
1520 |
3264 |
3896 |
5523 |
6891 |
7887 |
Exhaust Flange Diameter |
mm |
1*125 |
1*125 |
2*125 |
2*125 |
2*125 |
1*250 |
1*250 |
1*250 |
1*250 |
1*250 |
Charging Alternator Capacity |
A |
35 |
35 |
35 |
35 |
35 |
55 |
55 |
55 |
55 |
55 |
Starting Voltage |
V |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
24 |
Thermal Balance |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
JW Coolant Heat |
± 8% kW |
99 |
122 |
142 |
184 |
220 |
317 |
372 |
532 |
678 |
769 |
CAC Intercooler Heat |
± 8% kW |
 |
 |
 |
 |
 |
50 |
60 |
85 |
107 |
121 |
Exhaust Heat up to 120°C |
± 8% kW |
115 |
142 |
161 |
208 |
265 |
364 |
431 |
571 |
709 |
802 |
Energy Input |
 kW |
462Â |
571Â |
679Â |
860Â |
1067Â |
1531Â |
1809Â |
2504Â |
3160Â |
3559Â |
ELectrical Efficiency |
% |
34.6 |
35 |
36.8Â |
37.2Â |
37.5Â |
39.2Â |
39.8Â |
40.9Â |
40.5Â |
40.8Â |
Mechanical Efficiency |
% |
37.2Â |
37.4Â |
39.3Â |
39.7Â |
39.8Â |
41.1Â |
41.5Â |
42.5Â |
42.0Â |
42.2Â |
Thermal Efficiency |
% |
46.3Â |
46.2Â |
44.6Â |
45.6Â |
45.5Â |
44.5Â |
44.4Â |
44.1Â |
43.9Â |
44.1Â |
Total Efficiency |
% |
80.9Â |
81.2Â |
81.4Â |
82.8Â |
83.0Â |
83.7Â |
84.2Â |
85.0Â |
84.4Â |
84.9Â |
Gas Consumption |
MJ/kWh |
10.40Â |
10.29Â |
9.78Â |
9.68Â |
9.60Â |
9.18Â |
9.05Â |
8.80Â |
8.89Â |
8.82Â |
Generator Parameter-MECC ALTE |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Generator Model |
 |
ECO38-3SN/4 |
ECO38-2LN/4 |
ECO38-3LN/4 |
ECO40-2S/4 |
ECO40-1L/4 |
ECO43-2SN/4 |
ECO43-1LN/4 |
ECO43-VL/4 |
ECO46-2S/4 |
ECO46-1L/4 |
Generator Prime Output |
kW |
180 |
240 |
280 |
360 |
440 |
744 |
880 |
1120 |
1440 |
1680 |
Generator Efficiency @ 0.8PF |
 |
93.0% |
93.5% |
93.6% |
93.7% |
94.2% |
95.4% |
95.9% |
96.2% |
96.4% |
96.6% |
Genset Dimension |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Length |
mm |
3100 |
3100 |
3300 |
3500 |
3600 |
4600 |
4600 |
4500 |
5000 |
5000 |
Width |
mm |
1300 |
1300 |
1500 |
1500 |
1500 |
2190 |
2190 |
1600 |
1600 |
1600 |
Height |
mm |
1700 |
1700 |
2000 |
2000 |
2000 |
2300 |
2300 |
2200 |
2300 |
2300 |
Genset Weight |
kg |
2500 |
2500 |
3500 |
3900 |
4300 |
7350 |
7650 |
10500 |
13500 |
13500 |
Solder Ring Bronze Fittings
solder ring Bronze Fittings produced as kembla and connex,the lead of the solder is much lower than them,solder ring bronze fittings,pre-solder bronze fittings,yorkshire solder ring fittings,connex solder ring fittings,solder ring gunmetal fittings,solder ring bronze fittings,pre-solder bronze fittings,yorkshire solder ring fittings,connex solder ring fittings,solder ring gunmetal fittings
solder ring bronze fittings,pre-solder bronze fittings,yorkshire solder ring fittings,connex solder ring fittings,solder ring gunmetal fittings
Taizhou Runde Company , https://www.zjbrassfittings.com